HPLC
Analytical, Semi-Prep and Preparative HPLC Systems
A user friendly and highly functional gradient controller. The large LCD screen allows over 1000 lines to be programmed with ease. Precise and easy programming and control through the instrument keypad or the Sharp 3300 software. All wetted components can be changed from stainless steel to PEEK or Titanium as well as semi-preparative and preparative to better meet the needs of scientists today.

Ensure the highest quality and reproducibility in purification.
HPLC Analytical 3300™
- 10 mL pump heads
- Flow range 0.001 – 9.999 mL/min
- Flow rate accuracy: +/- 0.5% at 1 mL/min
- Flow rate precision: RSD <0.1% measurement at 1 mL/minute
- Options of stainless steel or PEEK tubing
- 42 Mpa maximum working pressure, stainless steel tubing; 30 Mpa maximum working pressure, PEEK
HPLC Semi-Prep 3300™
- 50 mL pump heads
- Flow range 0.01 – 49.99 mL/min
- Flow rate accuracy: +/- 0.5% at 1 mL/min
- Flow rate precision: RSD <0.1% measurement at 1 mL/ minute
- Options of stainless steel or PEEK tubing
- 30 Mpa maximum working pressure, stainless steel tubing; 20 Mpa maximum working pressure, PEEK
- 2 Standard HPLC Semi-Preparative 3300TM pumps equipped with 50 mL pump heads
- Standard HPLC Semi-Preparative 3300TM UV/Vis variable wavelength detector equipped with semi- preparative flow cell
- Manual injection valve with high capacity loop
HPLC Preparative 3300™
- 2 Preparative HPLC pumps with 100 mL, 250 mL, 500 mL or 1000 mL pump heads
- Preparative UV/Vis Variable wavelength HPLC detector
- Manual injection valve with 2 mL loop
- 2 HPLC Preparative 3300TM pumps with 100 mL, 250 mL, 500 mL or 1000 mL pump heads
- HPLC Preparative 3300TM UV/Vis Variable wavelength detector
- Manual injection valve and pump delivery of sample
- Different DAC Columns(mm) – 50,100, 150, 200, 250, 300, 400…800
HPLC 3300™ Detector
The HPLC 3300TM detector is an all-digital UV-VIS spectrophotometric detector. The measurement range of the HPLC 3300TM detector is 190 nm – 700 nm. The standard light source is a deuterium lamp with an optional tungsten-halogen lamp.
- Wavelength accuracy: within +/- 1nm
- Wavelength reproducibility: 0.2 nm
- Detection range: 0-2 AU
- Baseline noise: 1 x 10-5 AU/h, Dynamic flow rate 1mL/min, methanol/water 80/20, wavelength 254 nm
- Baseline drift: 1 x 10-4 AU/h, Dynamic flow rate 1mL/min, methanol/water 80/20, wavelength 254 NM

Easy Access
Quick and easy access to all wetted components without dismantling the instrument.